Skip to content
Skip to main content
< Back
Table of Contents

This guide provides a list of HKC Alarm Fault Codes broken down by Fault type.


1. Power Faults

Below is a table of HKC Alarm Power faults:

 

Alarm Fault NameFault AbbreviationDescription
Mains FaultMains Flt / Mains FaultMains Fault – Mains AC electrical power to the control panel has failed or been disconnected.
Battery LowBatt Low / Panel Batt LowLow Battery – Control panel internal backup battery voltage is low
Battery FailBatFail / Battery FailBattery Fail – Control panel backup battery failed its automatic load test or is disconnected
PSU Mains FaultPSU MainsAn auxiliary Power Supply Unit (PSU) has lost its mains AC power input.
PSU Low BatteryPSU LowBattBackup battery connected to an auxiliary Power Supply Unit is low on voltage.
Aux Power Supply BatteryPSU DeepDisThe Auxiliary Power Supply Unit backup battery has reached a deep-discharge level.
DTV Low BatteryDTV Low BatLow battery voltage detected on the DTV dialler module.

2. Tamper Faults

Below is a table of HKC Alarm Tamper faults:

 

Alarm Fault NameFault AbbreviationDescription
General TamperTam / Tamper ActivationGeneral tamper switch activation. A panel lid, sensor cover, or tamper loop circuit was opened.
Tamper FaultTam flt / Tamper FaultWiring fault, short circuit, or open circuit detected on a dedicated tamper loop.
Keyboard TamperRK1 Tamper / RK2 TamperRemote Keypad 1 or 2 cover was opened, or the keypad was removed from its wall mounting.
Siren Tamp / Bell TampSABB Tamper / BelTamExternal SABB bell box cover removed or pry-off wall tamper switch activated.
Internal Bell TamperInt Bell TamInternal siren housing cover opened or internal sounder tamper circuit disconnected.
Perimeter TamperPerimeter Tamper / Perim. AlarmTamper or open circuit on perimeter sensors (e.g. window shock sensors or door contacts).

3. Wireless Faults

Below is a table of HKC Alarm Wireless faults:

 

Alarm Fault NameFault AbbreviationDescription
RF Low BatteryRF Low BattLow battery on a wireless detector (PIR motion sensor, door/window contact, inertia shock sensor, smoke/CO detector).
Fob Low BatteryFob Low BattLow battery in a wireless RF keyfob.
RFI Low BatteryRFI Low BattLow battery on a wireless device connected via an RF repeater/interface module.
RF JammingRF Jam DetectRadio-frequency jamming or severe signal interference detected on the 868 MHz wireless channel.
RFI SupervisRFI SupervisRadio communication loss between an RF repeater and a wireless device.
Radio CommsSupervisory / Supervisory SignalRadio communication between the panel and a wireless detector was lost or interrupted.

 

4. Network & Comms Faults

Below is a table of HKC Alarm Network & Comms faults:

 

Alarm Fault NameFault AbbreviationDescription
Telephone landline failureLine Flt / DLR Line Flt / DTV Line FltTelephone landline connection failure or physical cable disconnection.
Telephone line faultDLR LnFlt-OH / DTV LnFlt-OHTelephone line fault caused by a premises phone handset left off-hook.
IP Comms FaultComFlt / DLR Coms / DTV ComsCommunication path failure between dialler/module and the monitoring station or SecureComm cloud server over WiFi, LAN/Ethernet, or cellular link.
Dialler FaultDialler FTC / DLR FTC / DTV FTCFail To Communicate: dialler failed to report an alarm signal to monitoring station or app over phone or IP/WiFi connection.
SMS FaultDLR SMS FTC / DTV SMS FTCOutgoing SMS text message notification failed to transmit.
Failed Voice NotificationDTV VoiceFTCOutgoing voice notification telephone call failed to reach the recipient.
No Dial ToneDLR NoD’tone / DTV NoD’toneDialler cannot detect a dial tone on the telephone line.
GSM SignalGSM Jam / GSM Jam DetectCellular signal jamming or severe radio noise detected on the GSM network connection.
Check in FailChk In FailScheduled supervisory check-in signal failed to reach central monitoring station over IP (WiFi/LAN) or cellular network.

5. Hardware & System Faults

Below is a table of HKC Alarm Hardware & System faults:

 

Alarm Fault NameFault AbbreviationDescription
Battery FuseBat.FuseThe control panel’s main backup battery fuse is blown or open.
Auxiliary FuseAux FuseControl panel auxiliary 12V power supply output fuse is blown or open.
Internal Bell/Siren FuseInt.FuseInternal siren/sounder power output fuse has blown or opened.
External Bell/Siren FuseExt.Fuse / Bel.FuseExternal bell/siren power output fuse has blown or opened.
Strobe LightStrbFuseStrobe light power output fuse is blown or open.
Data Bus ErrorDev Data ErrData bus transmission error between the control panel and an expander or keypad module.
General System FaultFltGeneral system fault warning indicator displayed on the keypad screen / status LED.
Service DueService Due … Contact EngineerProgrammed service interval timer (Wks 2 Service) has expired, prompting routine maintenance.

 

 

Need assistance clearing an engineer lock or replacing a panel battery? Ciz ICT is a PSA-licensed security installer (PSA #11346). Contact our Dublin office on 01 912 5130 or Kerry on 066 716 5020.